	<entry>
		<id>https://becomwiki.live.md-websolutions.com/index.php?title=Argos/Sentis_Firmware_Update&amp;diff=8&amp;oldid=prev</id>
		<title>Peter: 1 Version importiert</title>
		<link rel="alternate" type="text/html" href="https://becomwiki.live.md-websolutions.com/index.php?title=Argos/Sentis_Firmware_Update&amp;diff=8&amp;oldid=prev"/>
		<updated>2023-10-31T08:03:04Z</updated>

		<summary type="html">&lt;p&gt;1 Version importiert&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;de-AT&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Nächstältere Version&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Version vom 31. Oktober 2023, 10:03 Uhr&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;de-AT&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(kein Unterschied)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://becomwiki.live.md-websolutions.com/index.php?title=Argos/Sentis_Firmware_Update&amp;diff=7&amp;oldid=prev</id>
		<title>en&gt;Peter: 1 Version importiert</title>
		<link rel="alternate" type="text/html" href="https://becomwiki.live.md-websolutions.com/index.php?title=Argos/Sentis_Firmware_Update&amp;diff=7&amp;oldid=prev"/>
		<updated>2023-08-22T19:35:45Z</updated>

		<summary type="html">&lt;p&gt;1 Version importiert&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Neue Seite&lt;/b&gt;&lt;/p&gt;&lt;div&gt;==Firmware Update==&lt;br /&gt;
&lt;br /&gt;
A firmware update will update the camera&amp;#039;s kernel image (Linux) and root file system, which includes the camera software. It will keep your register map (including offset calibration). The update instructions are valid for the [[#Argos_3D-P23x|Argos3D P23x]], [[#Argos_3D-P32x|P32x]], and [[#Argos_3D-P33x|P33x]] series, as well as the [[#Sentis_ToF_-_P510|Sentis M520]] and [[#Sentis3D_-_M530|M530]]. If you would like to perform a firmware update on a device not listed here, please contact [https://www.becom-group.com/en/becom-systems/sales-support/| customer support].&lt;br /&gt;
&lt;br /&gt;
;In order to update your Argos/Sentis ToF product, please follow these steps:&lt;br /&gt;
* &amp;lt;span style=&amp;quot;color:#cc0000&amp;quot;&amp;gt;Please ensure that power is stable during an update operation.&amp;lt;span&amp;gt;&lt;br /&gt;
* Download the firmware binary loader file provided by BECOM Systems.&lt;br /&gt;
* Download and start the [[Blt_ToF_Suite|BltTofSuite]] provided by BECOM Systems.&lt;br /&gt;
* Connect to the Argos/Sentis device.&lt;br /&gt;
:[[Image:Suite_Connect_cursor.png|300px]]&lt;br /&gt;
* Make sure your camera is connected and accessible via TCP/IP.&lt;br /&gt;
* Open Tools/Downloader.&lt;br /&gt;
:[[Image:Suite_Connect_Downloader.png|300px]]&lt;br /&gt;
* Select &amp;quot;Application&amp;quot; from the dropdown menu.&lt;br /&gt;
* Click on &amp;quot;Choose file...&amp;quot; and select the firmware binary provided by BECOM Systems.&lt;br /&gt;
* Click on &amp;quot;Write&amp;quot; and wait for the popup window saying &amp;quot;Flash update finished successfully&amp;quot;.&lt;br /&gt;
:[[Image:Suite_Downloader_Application.png|300px]]&lt;br /&gt;
* Click on &amp;quot;Reset device&amp;quot; to reboot the Argos/Sentis device.&lt;br /&gt;
* The camera boots the new firmware and is ready for use.&lt;br /&gt;
* &amp;lt;span style=&amp;quot;color:#cc0000&amp;quot;&amp;gt;&amp;#039;&amp;#039;&amp;#039;In case the update fails, please retry, and don&amp;#039;t reboot before!&amp;#039;&amp;#039;&amp;#039;&amp;lt;span&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Firmware Recovery ===&lt;br /&gt;
In case a new firmware can&amp;#039;t be loaded for 3 times, the camera is able to recover your old firmware version.&lt;br /&gt;
&lt;br /&gt;
You can detect that this happened (besides the very long boot time) by reading the &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;Status&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; register once the camera is up again - if bit 8 is set, the old firmware was restored.&lt;br /&gt;
&lt;br /&gt;
==Lens Calibration Update==&lt;br /&gt;
&lt;br /&gt;
When using a different lens than the standard lens it is necessary to flash new lens parameters. Please get in contact with BECOM Systems to get further support for different lenses.&lt;br /&gt;
&lt;br /&gt;
;In order to update your lens parameters, please follow these steps:&lt;br /&gt;
* Download the lens parameters binary file provided by BECOM Systems.&lt;br /&gt;
* Download and start the [[Blt_ToF_Suite|BltTofSuite]] provided by BECOM Systems.&lt;br /&gt;
* Connect to the Argos/Sentis device.&lt;br /&gt;
:[[Image:Suite_Connect_cursor.png|300px]]&lt;br /&gt;
* Make sure your camera is connected and accessible via TCP/IP.&lt;br /&gt;
* Open Tools/Downloader.&lt;br /&gt;
:[[Image:Suite_Connect_Downloader.png|300px]]&lt;br /&gt;
* Select &amp;quot;LensCalibration&amp;quot; from the dropdown menu button.&lt;br /&gt;
* Click on &amp;quot;Choose file...&amp;quot; and select the calibration file provided by BECOM Systems.&lt;br /&gt;
* Click on &amp;quot;Write&amp;quot; and wait for the popup window saying &amp;quot;Flash update finished successfully&amp;quot;.&lt;br /&gt;
:[[Image:Suite_Downloader_Lenscalibration.png|300px]]&lt;br /&gt;
* Set register &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;HardwareConfiguration&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039; to the lens opening angle identifier that came with the lens calibration file.&lt;br /&gt;
* In any X/Y/Z image mode the 3D data adjusts to the new lens immediately.&lt;br /&gt;
&lt;br /&gt;
Most ToF sensors can store several lens calibrations, as long as they have different opening angle identifiers. By changing register &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;HardwareConfiguration&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;, XYZ point cloud calculation can switch between these calibrations.&lt;br /&gt;
&lt;br /&gt;
== Bootloader Update==&lt;br /&gt;
&lt;br /&gt;
Most ToF sensors use U-Boot as boot loader. Naturally, your camera was shipped with the boot loader pre-installed. Usually, there is no need to update the boot loader, except if your new firmware comes with a boot loader binary also.&lt;br /&gt;
&lt;br /&gt;
;In order to update your Argos/Sentis bootloader, please follow these steps:&lt;br /&gt;
* &amp;lt;span style=&amp;quot;color:#cc0000&amp;quot;&amp;gt;&amp;#039;&amp;#039;&amp;#039;Important! Please ensure that power is stable during an update operation, otherwise the device may not respond anymore!&amp;#039;&amp;#039;&amp;#039;&amp;lt;span&amp;gt;&lt;br /&gt;
* Download the bootloader binary loader file provided by BECOM Systems.&lt;br /&gt;
* Download and start the [[Blt_ToF_Suite|BltTofSuite]] provided by BECOM Systems.&lt;br /&gt;
* Connect to the Argos/Sentis device.&lt;br /&gt;
:[[Image:Suite_Connect_cursor.png|300px]]&lt;br /&gt;
* Make sure your camera is connected and accessible via TCP/IP.&lt;br /&gt;
* Open Tools/Downloader.&lt;br /&gt;
:[[Image:Suite_Connect_Downloader.png|300px]]&lt;br /&gt;
* Select &amp;quot;Bootloader&amp;quot; from the dropdown menu button.&lt;br /&gt;
:[[Image:Suite_Downloader_Bootloader.png|300px]]&lt;br /&gt;
* Click on &amp;quot;Choose file...&amp;quot; and select the bootloader binary provided by BECOM Systems.&lt;br /&gt;
* Click on &amp;quot;Write&amp;quot; and wait for the popup window &amp;quot;Flash update finished successfully&amp;quot;.&lt;br /&gt;
* Click on &amp;quot;Reset device&amp;quot; to reboot the Argos/Sentis device.&lt;br /&gt;
* The camera reboots with the new bootloader.&lt;br /&gt;
&amp;lt;span style=&amp;quot;color:#cc0000&amp;quot;&amp;gt;&amp;#039;&amp;#039;&amp;#039;In case the update failed: DON&amp;#039;T REBOOT! Retry updating the boot loader.&amp;#039;&amp;#039;&amp;#039;&amp;lt;span&amp;gt;&lt;/div&gt;</summary>