<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="de-AT">
	<id>https://becomwiki.live.md-websolutions.com/index.php?action=history&amp;feed=atom&amp;title=Argos_3D_-_P100</id>
	<title>Argos 3D - P100 - Versionsgeschichte</title>
	<link rel="self" type="application/atom+xml" href="https://becomwiki.live.md-websolutions.com/index.php?action=history&amp;feed=atom&amp;title=Argos_3D_-_P100"/>
	<link rel="alternate" type="text/html" href="https://becomwiki.live.md-websolutions.com/index.php?title=Argos_3D_-_P100&amp;action=history"/>
	<updated>2026-05-13T14:15:37Z</updated>
	<subtitle>Versionsgeschichte dieser Seite in BECOM Systems Support</subtitle>
	<generator>MediaWiki 1.43.5</generator>
	<entry>
		<id>https://becomwiki.live.md-websolutions.com/index.php?title=Argos_3D_-_P100&amp;diff=212&amp;oldid=prev</id>
		<title>Peter: 1 Version importiert</title>
		<link rel="alternate" type="text/html" href="https://becomwiki.live.md-websolutions.com/index.php?title=Argos_3D_-_P100&amp;diff=212&amp;oldid=prev"/>
		<updated>2023-10-31T08:03:08Z</updated>

		<summary type="html">&lt;p&gt;1 Version importiert&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;de-AT&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Nächstältere Version&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Version vom 31. Oktober 2023, 10:03 Uhr&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;de-AT&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(kein Unterschied)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://becomwiki.live.md-websolutions.com/index.php?title=Argos_3D_-_P100&amp;diff=211&amp;oldid=prev</id>
		<title>en&gt;Peter: 1 Version importiert</title>
		<link rel="alternate" type="text/html" href="https://becomwiki.live.md-websolutions.com/index.php?title=Argos_3D_-_P100&amp;diff=211&amp;oldid=prev"/>
		<updated>2023-08-22T19:35:49Z</updated>

		<summary type="html">&lt;p&gt;1 Version importiert&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Neue Seite&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[[File:Argos3D-P100_pers_W300.png|right|Argos3D-P100]]&lt;br /&gt;
&lt;br /&gt;
The upcoming Argos&amp;lt;sup&amp;gt;3D&amp;lt;/sup&amp;gt; camera platform stands for state of the art processor technology combined with outstanding image processing software to build a intelligent embedded camera system integrated into a smart housing with high quality optics.&lt;br /&gt;
&lt;br /&gt;
[https://www.becom-group.com/becom-systems-time-of-flight-solutions/tof-3d-kameras/argos-kameras/argos3d-p100/ Product Page]&lt;br /&gt;
&lt;br /&gt;
;Quick Start&lt;br /&gt;
: [https://datasheets.becom-group.com/goto/Argos/3D/P/100/ Quick Start Guide]&lt;br /&gt;
:HowTo: [[Firmware Update with LightVis|Firmware update with LightVis]]&lt;br /&gt;
&amp;lt;!--;Product description--&amp;gt;&lt;br /&gt;
&lt;br /&gt;
;Manuals&lt;br /&gt;
: [https://datasheets.becom-group.com/goto/Argos/3D/P/100/ User Manual]&lt;br /&gt;
: [[Argos3D - P100 Offset Calibration|Offset Calibration Guide]]&lt;br /&gt;
&lt;br /&gt;
;Hardware&lt;br /&gt;
: The Argos&amp;lt;sup&amp;gt;3D&amp;lt;/sup&amp;gt; - P100 Camera supports the use of an additional external light source ([[ToF-Flash]]). The [[Argos_3D_-_P100_External_Illumination_Guide|External Illumination Guide]] describes how.&lt;br /&gt;
&lt;br /&gt;
;Software&lt;br /&gt;
: &amp;#039;&amp;#039;Bluetechnix &amp;#039;Time of Flight&amp;#039; API&amp;#039;&amp;#039;&lt;br /&gt;
:: The Argos3D-P100 camera is supported by our [[Bluetechnix &amp;#039;Time of Flight&amp;#039; API|ToF API]].&lt;br /&gt;
&amp;lt;!--: &amp;#039;&amp;#039;PMDSDK Documentation&amp;#039;&amp;#039;&lt;br /&gt;
::The Argos&amp;amp;reg;&amp;lt;sup&amp;gt;3D&amp;lt;/sup&amp;gt; P100 Camera can be accessed and controlled via the SDK which can be included as a library. See the [[PMDSDK_/_PMDMDK_User_Manual|PMDSDK / PMDMDK User Manual]]--&amp;gt;&lt;br /&gt;
: &amp;#039;&amp;#039;Applying lense correction&amp;#039;&amp;#039;&lt;br /&gt;
::The Argos&amp;lt;sup&amp;gt;3D&amp;lt;/sup&amp;gt; - P100 Camera provides a calibration file for precise 3D position calculation. See the [[Lense Calibration Manual|Lense Calibration Manual]]&lt;br /&gt;
: &amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;#039;&amp;lt;big&amp;gt;&amp;lt;span style=&amp;quot;color:#FFFFFF; background:#1E90FF;&amp;quot;&amp;gt;&amp;amp;nbsp;Windows 8&amp;amp;nbsp;&amp;#039;&amp;#039;&amp;#039;&amp;lt;/span&amp;gt;&amp;lt;/big&amp;gt; support&amp;#039;&amp;#039;&lt;br /&gt;
::For windows 8 support please download the latest support CD package from the [https://datasheets.becom-group.com/goto/Argos/3D/P/100/software software download section]. The latest packages contains a signed version of the driver.&lt;br /&gt;
&lt;br /&gt;
::If you use an older version of the driver please follow the steps below:&lt;br /&gt;
::* Open a command line and enter the command &amp;lt;pre&amp;gt;shutdown.exe /r /o /f /t 00&amp;lt;/pre&amp;gt; Attention: The computer restarts immediately, therefore save all data before executing this command. Alternatively, from Windows 8 control panel, choose &amp;#039;&amp;#039;&amp;#039;General&amp;amp;rarr;Under “Advanced Startup”&amp;amp;rarr;Restart now&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
::* After some time you will be prompted with a menu with following options.&lt;br /&gt;
:::*&amp;#039;&amp;#039;Continue&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Troubleshoot&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Turn off&amp;#039;&amp;#039;&lt;br /&gt;
:::&amp;amp;rarr; Choose &amp;#039;&amp;#039;Troubleshoot&amp;#039;&amp;#039;&lt;br /&gt;
::* Then the following menu appears:&lt;br /&gt;
:::*&amp;#039;&amp;#039;Refresh your PC&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Reset your PC&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Advanced Options&amp;#039;&amp;#039;&lt;br /&gt;
:::&amp;amp;rarr; Choose &amp;#039;&amp;#039;Advanced Options&amp;#039;&amp;#039;&lt;br /&gt;
::*&amp;#039;&amp;#039;The following menu appears:&lt;br /&gt;
:::*&amp;#039;&amp;#039;System Restore&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;System Image Recovery&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Automatic Repair&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Command Prompt&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;Windows Startup settings&amp;#039;&amp;#039;&lt;br /&gt;
:::&amp;amp;rarr; Choose &amp;#039;&amp;#039;Windows Startup Settings&amp;#039;&amp;#039;, then Click &amp;quot;Restart&amp;quot;.&lt;br /&gt;
::* Now the computer will restart and the boot menu appears. Choose “Disable Driver signature Enforcement” from the menu. Now Windows will start and you can do the installation of the driver that is not signed. &lt;br /&gt;
&lt;br /&gt;
;Firmware&lt;br /&gt;
: &amp;#039;&amp;#039;Available firmware binaries&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;v1.0.0&amp;#039;&amp;#039;&lt;br /&gt;
:::*&amp;#039;&amp;#039;v2.3.1&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
Be aware that a direct update from version v1.0.0 to v.2.3.1 using the BltTofSuite is not possible. To update from v1.0.0 please use the firmware update package (20151030_Argos-P100_FirmwareUpdater_v1.2.zip) available from the [https://datasheets.becom-group.com/goto/Argos/3D/P/100/software software download page]. An instruction on howto update is included in the zip file.&lt;br /&gt;
&lt;br /&gt;
;Download&lt;br /&gt;
: For software downloads, please refer to [https://datasheets.becom-group.com/goto/Argos/3D/P/100/software software download].&lt;br /&gt;
&amp;lt;!--:If you don&amp;#039;t have a valid Bluetechnix account, please sign up here: https://support.bluetechnix.com/software/CreateUser.aspx --&amp;gt;&lt;br /&gt;
If you encounter any problems feel free to contact us at [mailto:support@bluetechnix.com support@bluetechnix.com]&lt;br /&gt;
&lt;br /&gt;
[[Category:Argos3D-P100]]&lt;/div&gt;</summary>
		<author><name>en&gt;Peter</name></author>
	</entry>
</feed>